LCD 3.2E
Feature highlights
- Small, lightweight, continuous, real-time detector of CW agents and toxic chemicals.
- Enhanced IMS technology using a non-radioactive source.
- Communication port for use with computer, ear piece or network systems.
- 40 + hours on AA type batteries.
- Available in five colours
LCD (Lightweight Chemical Detector) represents a new generation of sophisticated yet small and lightweight chemical warfare agent detectors, which will revolutionise the soldier's personal protection in the 21st century. The LCD contains no radioactive source, has a volume of less than 30in³ and weighs less than 1 lb (0.45kg). See our complete brochure on LCD3.2E [more]
Principally used as an unobtrusive personal detector, the LCD constantly samples the air for traces of nerve(G), blister(H), TICs(T) or blood (H) and choking (T) agents, to enable the user to take appropriate action. When used in survey mode, the unit has the capability for checking cargo, equipment, personnel or facilities. Additionally, the unit can be deployed on fixed or mobile platforms, including vehicles, ships, aircraft and fixed site installations.
Equipped with an audible and/or visual alarm the unit incorporates an LED display mounted on the top face, to show operating status and give visual alarms (when worn), and a bar display on the front of the unit indicates concentration levels. In the event of an attack, the unit has the ability to recover quickly with a rapid clear-down time.
As part of the development, the detector has undergone successful testing with the UK Ministry of Defence, the US Department of Defence (DoD) and was originally designed to meet UK MoD requirements for the Lightweight Chemical Agent Detector (LCAD) programme. The LCD is currently in service within numerous other governments. Extensive trials have shown the highest level of performance of any detector of its kind. As a result, it remains the only participant in the trials for the US DoD JCAD Increment 1 programme.
The LCD 3.2E is user-friendly, highly reliable and field maintainable to minimise whole life cost. The only consumable items are standard commercially available AA batteries and the molecular sieve pack; both of which are replaceable in the field in less than two minutes and can be undertaken whilst wearing Individual Protective Equipment. Once deployed, the detector requires no calibration, lubrication or other scheduled maintenance. Accessories are available to further enhance the capability of the LCD 3.2E [more]
| Specifications | |
|---|---|
| Size: | 30 cubic ins / 492cm³ (Sizes exclude external switch toggles, clips, raincap and connectors) |
| Weight: | Not exceeding 1lb (0.454kg) without batteries |
| Colour: | Blue, Black, Green, Yellow and Beige |
| Temperature range: | Operating at -30°C to +40°C |
| Power supply: | Batteries Alkaline or Lithium Iron Disulphide |
| Battery life: | Alkaline Type - typically 30 hours above 10°C Lithium Type - typically 40 hours above 10°C |
| Data interface: | USB or RS485 |
| additional info | |
|---|---|
| Accessories |
See our Accessories page to enhance your LCD! |
LCD-3_2E_Brochure.pdf (1,73 MB)![]() |
See our new brochure describing the latest version of the well known Lightweight Chemical Detector (LCD). |
Associated products
HGVI
- Multiple sensors (orthogonal techniques) working together in one instrument
- Driven by H-Fusion™ , advanced software developed to interpret results of multiple sensors
- Non-radioactive IMS source
- Automatic Detection, Identification and Monitor modes of operation
SABRE 4000
- Lightest trace detector available
- Analyze either particle or vapor samples
- Weighs 7 lbs. with the standard 4-hour battery
- 3.5” color TFT display
APD2000
- Detects chemical warfare agents and civilian threats such as pepper spray and mace
- Provides agent identification
- Superior interferent resistance
- Powered by commercial alkaline or rechargable batteries
SABRE FR
- Chemical Warfare Agent and Toxic Industrial Chemical detection capability
- Weighs 7 lbs. with the standard 4-hour battery
- Analysis results in seconds
- 3.5" color TFT display
GasID
- Identifies unknown gases and vapors in minutes
- No user calibration required
- Large library of gases and vapor spectra
- ReachBack 24/7/365 Technical Support
LCD 3.3
- Capability to detect Chemical Warfare Agents (CWAs) at miosis levels
- Various languages programmed to customer preference
- Fully integrated advanced menu driven display
- Up to 100 hours of operation using commercial AA-type batteries
- The display can be configured to show the concentration in bar or numerical formats and includes accumulated dosage reporting
LCD-FR
- HazMat certification is not required
- Revolutionary non-radioactive IMS detection source
- Low cost, low maintenance and no calibration required
- ReachBack 24/7/365 Technical Support
Contact
For further information about this product, please contact us. [more]
News
29 July 2008 Smiths Detection to Supply Amtrak with Additional Advanced Portable Explosives Detection Systems [more]
15 July 2008 Smiths Detection Protects Nation’s Capital with Advanced Carry-on Baggage Screening in Area’s Three Major Airports [more]
09 July 2008 Smiths opens production plant for advanced X-ray detection systems [more]
25 June 2008 Smiths Detection Launches Smart Trigger for Biological Detection [more]
24 June 2008 Smiths Detection launches hand-held vapour detector for chemicals commonly used in improvised explosive devices [more]