Feature highlights:

  • Loud Alarm, 85 dB (A)
  • Vibrating alarm
  • Highly visible backlit display
  • Optional telemetry
  • Factory upgradeable firmware
  • Simple 2-button navigation
  • Extended dose rate alarms
  • Dual ultrabright LED alarm
  • Meets or exceeds applicable IEC and ANSI standards

Mirion Technologies provides a complete line of hardware and software products targeted to cargo inspectors and emergency responders.

Covering a wide range of X-Ray and Gamma radiation detection, our DMC 3000 Electronic Dosimeter represents over 25 years of real-world electronic dosimetry experience, continually refi ned through customer feedback.
The unique, high contrast and backlit LCD display provides a clear indication of wearer’s dose and ambient dose rate for deep dose equivalent. More importantly, multiple methods (audible, visual, and tactile) are utilized to alert the wearer of alarm conditions.
DMC 3000 provides all of this protection, for over 2500 hours of continuous use, with a single AAA battery.
Mirion Technologies provides users with additional tools for calibration, positive entry control, and remote monitoring.

Specifications

 
Physical Characteristics
  • Compliant with IEC 61526Ed. 3, ANSI 42.20(*)
    (*) isotropy 241Am and 137Cs with ± 75° angle
  • Measurement and display:
    ○ X and gamma energy range: 15 keV to 7 MeV
    ○ energy response better than ± 20% (typically ±10%) from 16 keV to 7 MeV
  • Accuracy Hp(10):
    ○ ± 10* (137Cs, ~ 24 mSv/h) ≤ ±10%* ,241Am,
    ○ ≤ ±19%** X-ray 16keV
    (*including ± 5% extended uncertainty K=2) ;
    (** including ± 9% extended uncertainty K=2)
  • Display units: mSv, μSv, or mrem
  • Display dose: 1 μSv to 10 Sv (0.1 mrem to 1000 rem)
  • Display rate: 0.01 mSv/h to 10 Sv/h (1 mrem/h to 1000 rem/h) or 0.001 mSv/h to 10 Sv/h (extended option)
  • Measurement range: 0.1 μSv/h to 10 Sv/h (0.01 mrem/h to 1000 rem/h)
  • Dose Rate Linearity:
    ○ ± 20 up to 10 Sv/h (1000 rem/h) (Co and X H30
    20 keV)
    ○ ± 20 up to 6 Sv/h (600 rem/h) (Pulsed X-rays 20
    ms width, 1, 10 & 20 pps)
  • Saturation indication above 10 Sv/h
Electrical Characteristics
  • Standard AAA (LR03) 1.5V Alkaline battery,
  • 9 calendar month battery life (typical, 8 h per day, 5 days per week in run mode, without excessive alarms*
  • 2500 h battery life in continuous run, without excessive alarm*
    *0.2% of the time in alarm
Mechanical Characteristics
  • Rugged, high impact polycarbonate-ABS case
  • Dimensions: 86 x 56 x 21 mm (3.4 x 2.2 x 0.8 in) without clip
  • Weight with alkaline battery and clip: < 84 g (2.9 oz)
  • Worn by a replaceable clips (2 different style back clips or one a front-facing clip for DMC worn inside the pocket)
Environmental Characteristics
  • Temperature range: -10°C to 50°C (14°F to 122°F): deviation in response less than ±5%
  • Humidity: 90% at 42°C (108°F)
  • Storage: -20°C to 71°C (-4°F to 160°F)
  • Shock, vibration and drop resistant (1.5 meters on concrete),
  • Waterproof IP67 1m (39 in) during 1 hour
  • EMC: complies and exceeds standards by a large argin ( compliant, certifi cate number: 153720)
  • MIL STD 461F RS103 (pulsed electric fi eld): exceeds 200V/m from 30 kHz to5 GHz
  • MIL STD 461F RS101 (magnetic field 30 Hz - 100 kHz)
  • Factory calibration approved under ISO/CEI 17025


Histogram Features

  • Histograms are saved to non-volatile memory (EEPROM) workers dose,1μSv (0.1 mrem) resolution stored in increments of 10 s, 1 min,10 min, 1 h or 24 h
  • Event log (alarms, faults, changes) marks events during the selected time periods
  • Stores data for several consecutive workers entries and exits (more than 1000 steps)


Display Features

  • Large LCD display with high quality white backlighting
  • 8 alpha-numeric digit display for full name display (scrolling) and fixed dose/rate display format
  • 3 top LED for Alarming (Red), gamma counting (Green) and Hp(0.07) or Neutron counting (Blue)
  • Two push buttons for an easy customized dosimetry and personal information display


Alarm Features

  • Dual tone alarming speaker with level of 85 dB (A) typical at 30 cm, frequency < 4800 Hz
  • Tactile alarm (vibrator)
  • High effi ciency red fl ash LED on front
  • 3 Top LEDs’ and display indicators
  • 2 dose/rate alarms, adjustable over the display range
  • 2 dose/rate pre-alarms, adjustable over the display range and acknowledgeable
  • Remaining time before alarm and run time alarms
  • Alarm on battery removal
  • Hands free communication 125 kHz frequency
  • Range of communication with LDM 220: 10 cm (3.9 in)
  • Backward compatibility with existing readers (LDM 2000, LDM 220)

Support Form

 

Send a Support Request

Fill in your details below and we'll get back to you as soon as we can.

Thank You

Step 1. Choose your country

Step 2. Choose your product

Step 3. Fill in your support request.

Alternatively contact us by telephone

 

Contact us

 

Ask a question

Fill in your details below, and we'll get back to you just as soon as we can. Thank you.

or you can



Speak to Our Sales Team

Ask us a Question

Submit your question and we’ll get back to you as soon as possible.

Submit a query

Language

LinkedinYoutubeTwitter

Keep in touch